搜索结果: 1-15 共查到“化学 Development”相关记录21条 . 查询时间(0.187 秒)
Development and Characterization of Caspase Activatable GFP and a Family of Fluorescent Reporters
apoptosis GFP
2014/11/20
The cellular process of programmed cell death, or apoptosis, is critical in homeostasis and development. In addition it's misfunction is implicated in an array of disease states from cancer to neurode...
Development of Mass Spectrometry-Based Methods for Quantitation and Characterization of Protein Drugs: Transferrin as a Model Drug Delivery Vehicle
Mass Spectrometry O18 labeling Protein quantitation Transferrin
2014/11/20
In the last two decades, protein drugs have enjoyed a rapid growth and achieved a tremendous success in treating human diseases. However, the presence of physiological barriers greatly impedes the eff...
Development of a Simple and Low-cost Device for Fluorometric Determination of Selenium in Water Samples
Simple Low-cost Device Fluorometric Determination Selenium Water Samples
2010/10/25
A portable spectrofluorometer device comprising an ultraviolet LED (380 nm) as a light source, an LED driver, a microsyringe as a cell, an optical fiber cable, a CCD spectrometer and a personal comput...
Performance evaluation of platinum-based catalysts for the development of proton exchange membrane fuel cells
Methanol catalysts cyclic voltammetry PEM fuel cell
2010/4/30
Platinum-based catalysts are considered the most efficient catalysts for triggering electrochemical reactions in proton exchange membrane (PEM) fuel cells. In the present study, commercial catalysts c...
Development of a UPLC-ESI-MS/MS Assay for 20(S)-Protopanaxadiol and Pharmacokinetic Application of Its Two Formulations in Rats
Pharmacokinetic Application Two Formulations Rats
2010/2/25
An ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method was developed to investigate 20(S)-protopanaxadiol (PPD) pharmacokinetics in rats. Rat plasma s...
Development of the Hard-X-ray Angle Resolved X-ray Photoemission Spectrometer for Laboratory Use
X-ray Photoemission Spectrometer Laboratory Use
2010/1/1
This article reports development of a practical laboratory hard X-ray photoelectron spectroscopy (HXPS) system by combining a focused monochromatic Cr Kα X-ray source, a wide angle acceptance objectiv...
Development of Interdigitated Array Electrodes with Surface-enhanced Raman Scattering Functionality
Interdigitated Array Electrodes Surface-enhanced Raman Scattering Functionality
2010/1/1
Interdigitated array electrodes with surface-enhanced Raman scattering (SERS) functionality for in situ qualitative and quantitative analysis of electroactive species are demonstrated. Gold nanostruc...
Development of a Compact System for the Determination of Lead Using a Liquid Core Waveguide and a Blue Diode as a Light Source
Liquid Core Waveguide Blue Diode Light Source
2010/1/1
A simple and compact system was developed for the on-site analysis of lead in environmental water samples. The system consisted of a custom-made blue diode as a light source, a liquid core waveguide (...
Errata: Development of Spin-Polarized Ion Scattering Spectroscopy
Development Spin-Polarized Ion Scattering Spectroscopy
2010/1/1
On page 84, the polarity of SP-ISS should be reversed in Fig. 6. The corrected figure is shown below. Accordingly, the polarity of the SP-ISS spin asymmetry on page 85 line 16 should also be reversed....
Development of a Discrete Flow System Using a Microsyringe as a Cell for the Photometric Determination of Iron
Microsyringe Cell Photometric Determination Iron
2010/1/1
A simple discrete flow system for the photometric determination of iron using a glass syringe as a mixer of a solution and as a sample cell has been developed. The system was assembled from a coupler...
Development of Signaling Echo Method for Cell-based Quantitative Efficacy Evaluation of Anti-cancer Drugs in Apoptosis without Drug Presence Using High-precision Surface Plasmon Resonance Sensing
Signaling Echo Method Cell-based Quantitative Efficacy Evaluation Anti-cancer Drugs
2010/1/1
We propose a rapid and label-free quantitative evaluation of anti-cancer drug efficacy in apoptosis using live cancer cells cultured on a sensor chip. The resultant custom-made, high-precision surface...
Development and Validation of Spectrophotometric Methods for Estimating Amisulpride in Pharmaceutical Preparations
Spectrophotometric Methods Estimating Amisulpride Pharmaceutical Preparations
2010/1/1
Five simple, sensitive, accurate and rapid visible spectrophotometric methods (A, B, C, D and E) have been developed for estimating Amisulpride in pharmaceutical preparations. These are based on the d...
Development of a ZnO-modified Light-Scattering Sensor for the Detection of Alcohols
a ZnO-modified Light-Scattering Sensor Alcohols
2010/1/1
A light-scattering sensor that incorporated zinc oxide (ZnO) nanoparticles was developed and characterized in this study. Evenly distributed nanostructured ZnO materials were formed on the sensing ele...
Development of Alumina Supported Alkaline Catalysts Used for Biodiesel Production
Biodiesel canola oil heterogeneous catalyst Al2O3 supported catalysts
2009/4/30
The transesterification of canola oil with methanol was studied in a heterogeneous system, using g-Al2O3 supported alkaline catalysts. All the catalysts were prepared by incipient-wetness impregnation...